2.9.0

Release date: September 23 2019

New Features

Plotting profiles via GPS coordinates

It is now possible to navigate profiles within an RSK based on the GPS location for which the data was collected.

Others
  • Added fw 1.107 (104)

Improvements

  • RSK-4895 - Display sensor serial number on calibration tab where applicable
  • RSK-4969 - All time displays are now in 24h format
  • RSK-5238 - Added 2pt calibration feature for RBRcoda T.ODO
  • RSK-5566 - Move to Java 8 java.time for all time related functions
  • RSK-6517 - Added better filtering to port names to minimize detection of Bluetooth devices
  • RSK-6677 - Added ST16 and ST17 sensor packs for T-string factory configuration
  • RSK-6711 - Added RBRcoda3 PAR simulation option
  • RSK-6715 - Fix error writing parameters to RSK file
  • RSK-6716 - Fix error initializing error table in RSK file
  • RSK-6718 - Added indicator to UI when Gen3 instrument is in simulation mode
  • RSK-6741 - Updated RSK calibration page to Gen3 format
  • RSK-6764 - Added STU17 and STU18 sensor packs for Seapoint Turbidity sensor factory configuration
  • RSK-6765 - Reduced Turner Cyclops Turbidity display range to 1500NTU
  • RSK-6767 - Added support for A-0-A factory configuration
  • RSK-6772 - Renamed ODO to T.ODO in all user manual content
  • RSK-6778 - Implemented support for keyboard accelerators
  • RSK-6781 - Updated list of reference devices for factory pressure calibration
  • RSK-6815 - Added support for output format caltext07 (Standard resolution (checksum))
  • RSK-6816 - Added retry mechanism when failure to update module firmware is detected
  • RSK-6824 - Closing a confirmation dialog now treated as a cancel action
  • RSK-6828 - Updated references to calibration services for factory calibrations

Bug Fixes

  • RSK-5462 - Calibration time stamps are shifting following an RSK upgrade
  • RSK-5323 - Easyparse files offer upgrade but don't produce usable RSK files following upgrade
  • RSK-6325 - Maximize memory for L2 doesn't always yield 100%
  • RSK-6438 - Exporting a profile to RSK doesn't produce consistent RSK file
  • RSK-6462 - Correcting channels are being displayed in customer mode data table
  • RSK-6473 - Opening BIN file can fail to open and not not inform user
  • RSK-6840 - Directional sampling parameters may be inconsistent and cause failure to enable
  • RSK-6492 - Factory mode can produce silent errors during shipping configuration
  • RSK-6570 - Gen3 instruments displaying 1999-12-31 as an end time
  • RSK-6619 - Auto deploy/stop/download has inconsistent menu state
  • RSK-6660 - Lock state is inconsistent for secured operations causing errors
  • RSK-6757 - Fast32 option missing for combinations of C.T.D instruments in simulator
  • RSK-6763 - Navigator download for an XR instrument doesn't actually download
  • RSK-6777 - Failure to open a binary wire walker file
  • RSK-6793 - Cannot stream/fetch XR instrument with fresh water conductivity
  • RSK-6813 - Some L2 instruments cannot fetch in certain scenarios
  • RSK-6818 - RSK sampling rate is not correct for original RBRsolo D|tide (type 3) downloads
  • RSK-6826 - Exporting to Matlab throws an error
  • RSK-6827 - Unable to connect to Microsalinometer over serial
  • RSK-6830 - Certificate acceptance dialog appears during application update process
  • RSK-6844 - Mapping between streamed/fetched data and active channels is broken when some channels are disabled
JavaScript errors detected